Assemble Fire Extinguishing Robot
Remove the ultrasonic sensor and two photoresistors.


Put on a fan module and two flame sensors.

You can make the fan module install further if the fan module and flame sensors interfere.

Wire up
Wire up the two flame sensors.

Flame Sensor |
Keyestudio 8833 Board |
|---|---|
G |
G |
V |
V |
A |
A1 |

Flame Sensor |
Keyestudio 8833 Board |
|---|---|
G |
G |
V |
V |
A |
A2 |
Wire up the fan module .

DC130 Motor |
Keyestudio 8833 Board |
|---|---|
G |
G |
V |
V |
IN+ |
D12 |
IN- |
D13 |
We adopt a model 18650 lithium battery with a pointed positive pole, whose power and capacity are not required.